I. Overview
The big three-phase synchronous motor for TK series air compressor is a high-overall performance series merchandise specially made and developed by our firm for the load of air compressor.
This sequence of motors adopts new technologies, new supplies, new procedures, beautiful substance selection, and refined manufacturing. It has the characteristics of tiny dimension, mild excess weight, gorgeous appearance, substantial effectiveness, reduced sounds, lower vibration, protected and reputable operation, and handy use and upkeep.
2. Implementation expectations
GB755 Rotating Motor Rating and Performance
Classification of GB/T997 rotary motor composition kind, set up variety and junction box place (IM code)
GB/T1571 3-period synchronous motor examination technique
GB/T1993 Rotating Equipment Cooling Approach
GB/T4942.1 Security class (IP) classification of the general framework of rotating electrical equipment
GB/T10068 The measurement, analysis and limit of mechanical vibration with a shaft middle top of 56mm and earlier mentioned
GB/T10069 Rotating Equipment Noise Measurement Approach and Limit
JB/T8667.one CZPT Situations of Massive A few-period Synchronous Motor Element 1: TK Series
three. Standard complex parameters
Electrical power assortment: 250~10000KW
Rated voltage: 6000, 10000V
Rated speed: 250, 273, 300, 333, 375, 428, five hundred, 600r/min
Rated frequency: 50HZ
Protection amount: IP00, IP20, IP23, IP44
Insulation class: F
Quota: SI
Cooling method: IC01, IC37, IC81W
Set up technique: IM7311, IM5710, IM7312, IM7315
*Can be manufactured in accordance to other parameters according to person wants
4, technical qualities
4.one The structural layout is affordable, safe and trustworthy, and the capacity to phase out of step is sturdy.
four.two The major insulation construction utilizing new insulating resources has higher voltage resistance and prolonged motor lifestyle.
4.3 The temperature increase margin is big. The motor adopts F-class insulation, and the temperature increase is assessed according to the temperature increase restrict of the B pole insulation.
four.4 The protection gadget is innovative and total.
4.one.1 The stator windings and bearings are equipped with temperature detection gadgets, which can detect, alarm and journey.
four.four.2 Shutdown area heater with anti-condensation impact.
4.five Large inertia. Motors with various moments of inertia can be created according to user demands.
Five, composition variety
5.one The total construction of this collection of motors is welded with metal plates for the body, end cover, and bottom plate. The motor is an independent cavity, and the slip ring can be created with various security amounts in accordance to consumer requirements.
five.2 Stator: The stator body is welded by steel plate. The motor stator outlet is led out by a large-voltage rubber cable. The outlet situation can be led out from the reduced component of the foundation or from the main junction box on the side of the motor.
The stator core is superimposed by minimal-decline silicon metal sheets, and the main sections are divided by radial air flow ducts.
The stator winding is F quality insulation, and the temperature rise is assessed in accordance to B grade to support lengthen the services daily life. It adopts VPI total dipping paint treatment, which has substantial electrical functionality, mechanical energy, insulation functionality, humidity resistance and thermal balance.
5.three The rotor magnetic pole main is produced of laminated steel plates, and has various buildings such as magnetic pole screws and T tails. The rotor bracket has ventilation holes and is outfitted with a admirer, which can properly handle the temperature rise of the rotor.
5.four Adopt seat sort spherical sliding bearing. The bearings are insulated to stop shaft currents.
Use new lubricating oil and slim-walled bearing alloy tiles, and established electromagnetic centerline indicators.
5.5 In accordance to consumer wants, the slip ring can be developed as a optimistic stress ventilation framework to enhance the protection of the motor. The complete duration of the motor with the positive pressure air flow structure of the slip ring is slightly improved.
six. Conditions of Use
six.one Voltage fluctuation: ±5% (It can run underneath ±10% beneath the situations of seven.3 in GB755)
6.two Frequency fluctuation: ±2%
six.three The altitude does not exceed 1000m
six.4 The greatest ambient temperature does not exceed +40ºC, and the least is 0ºC.
7, design description
 TK1250-16/2150

Outer diameter of stator punch (Φ2150mm)

Number of poles (16 poles)

Rated energy (1250KW)
A few-stage synchronous motor for compressor
8. Ordering directions
eight.one Before putting an purchase, make sure you refer to the merchandise catalog of this sequence to explain the necessary product design, requirements and other info. If there is a discrepancy in between the specs and the samples, remember to contact our organization.
8.two The motor product, rated electrical power, synchronous speed, rated voltage, rated frequency, defense stage, second of inertia, rotation route, installation kind, etc. need to be indicated when ordering.
8.three The sample technological info sheet only lists the related information of motors with rated voltages of 6KV and 10KV. If consumers require other voltage ranges, our company can also supply appropriate technical data when buying.
eight.4 The specialized data and proportions in the sample are only for reference when the user selects the design. The formal details will be presented by the firm following the agreement or complex agreement is signed.
8.5 If there are any other specific requirements, make sure you provide the requirements and sign the related technical agreement when ordering.